Eaton Products
RVAC Ring Main Unit
RVAC RMU use SF6 gas insulation, load break switch unit uses 3-position SF6 switch as breaking devices, allowing breaking rated current. Circuit breaker unit applies vacuum interrupters as its breaking device, can break short-circuit current. Based on the design concept of full insulation and fully sealed, all primary parts within RVAC RMU are fully sealed inside the stainless-steel main enclosure, protect to against condensation and external contami-nated environment; the protection degree of the main tank body is up to IP68, equipped with Cooper’s water-proofing touchable cable bond, which can provide effective protection against accidental flood in rainy climate.
SPD Series
SPD Series for Integration into or external Electrical Distribution Equipment.
Technical Data and Specifications :
- 20 kA nominal discharge current (In) rating (maximum rating assigned by UL).
- 50 through 400 kA surge current capacity ratings.
- 200 kA short-circuit current rating (SCCR).
- Standard : UL1449 4rd Edition and UL1283 7th Edition
CVX050 / CVX100
CVX050 / 100 models for Integration into or external Electrical Distribution Equipment.
Technical Data and Specifications
- 20kA nominal discharge current (In) rating (maximum rating assigned by UL).
- 50 and 100 kA surge current capacity
- 100 kA short-circuit current rating (SCCR).
- Standard : UL1449 4rd Edition
Aegis Series
Eaton AEGIS™ Series line filters and surge protectors are specifically designed to protect sensitive electronics from hazards that exist within a facility.
Technical Data and Specifications
- 5 kA nominal discharge current (In) rating.
- 60 kA surge current capacity ratings.
- 5 kA short-circuit current rating ( SCCR ).
- Rated Current 3-20A @120 or 240Vac.
- Standard : UL 1449 7th Edition and UL 1283 5th Edition.
Contactor transfer switches
Compact design and user friendly front access interface simplifies routine operation, testing, maintenance and user programming.
Technical Data and Specifications
- Rated for 40–3000 A and up to 600 V in two, Three or four-poles configurations.
- Available in open-delayed, open-in-phase and closed transition
- Automatic and non-automatic styles .
- Field-selectable multi-tap transformer panel permits operation on a wide range of system voltages .
Contactor bypass isolation transfer switches
Compact design and user friendly front access interface simplifies routine operation, testing, maintenance and user programming.
Technical Data and Specifications
- Rated for 100–3000 A and up to 600 V.
- Available in open-in-phase, open-delayed or closed transition .
- Front accessible with top and/or bottom entry available.
- Dual ATS technology allows both the ATS and the bypass switch to operate as automatic transfer switches .
- Draw-out capabilities on both ATS and bypass compartments allow preventive maintenance, inspection and testing to be accomplished while maintaining continuous power to the load.
- Safety interlock system.
- Field-selectable multi-tap transformer panel permits operation on a wide range of system voltages.
- Standard : UL 1008 Listed, Seismic Zone 4 qualified (CBC, IBC, UBC),
- OSHPD certification